Searching: TM G428Z3HD
| Nominal pressure range | ± 2,5kPa to 6MPa |
|---|---|
| Overpressure to 40 kPa fro m 60 kPa to 6MPa | 100 kPa 200 % nominal range |
| Error | max. 1% (0.5%) |
| Zero temperature error | typ. 0,1% max. 0,3 %/10°C |
| Span temperature error | typ. 0,1% max. 0,3 %/10°C |
| Compensated temp. range | 20 ÷ +70°C |
| Operating temp. range | -20 ÷ +85°C (non condensing) |
| Storage temperature | -25 ÷ 100°C |
| Supply voltage | 12 ÷ 36V dc |
| Supply current – output H | < 4mA |
| Output | 4 ÷ 20mA two-wire 0 ÷ 20mA three-wire 0 ÷ 10V three-wire 2 ÷ 10V three-wire |
| Operated position | arbitrary |
| Voltage strength | min. 1000V dc |
| Protection | min. IP 54 |
| Weight | cca 100g |
| Common-mode pressure for differential version | max. 1Mpa |
EMC – according to ČSN EN 61326-1
At the customer´s wish it is possible to secure a metrological verification of the transmitters at an accredited Calibration Service Centre.