| Code SV | D | 2 | 3 | 1 | N | 2 | U | B | D | | S |
pressure meassurement | D - differential | D | | | | | | | | | | |
---|
|
---|
exponent of pressure range | 2 - 102 Pa (hundreds Pa) | | 2 | | | | | | | | | |
---|
3 - 103 Pa (units kPa) | | 3 | | | | | | | | | |
|
---|
multiplicand of pressure range | 1 - 1,0 | | | 1 | | | | | | | | | |
---|
3 - 3,0 | | | 3 | | | | | | | | | 78,00 |
|
---|
accurancy | 1 - 1% | | | | 1 | | | | | | | |
---|
|
---|
pressure connection | R - quick-couple 5mm | | | | | R | | | | | | |
---|
V - hose 6mm | | | | | V | | | | | | |
N - one Touch Fitting 4mm | | | | | N | | | | | | |
M - one Touch Fitting 6mm | | | | | M | | | | | | |
O - one touch fitting 8mm | | | | | O | | | | | | |
|
---|
electrical connection | 2 - cable 1 m | | | | | | 2 | | | | | |
---|
5 - terminal block and grommet | | | | | | 5 | | | | | |
|
---|
analogue electrical output | U - analogue 4÷20mA, 0÷20mA, 0÷3V, 0÷10V | | | | | | | U | | | | |
---|
|
---|
digital electrical output | A - series RS232 | | | | | | | | A | | | |
---|
B - series RS485 | | | | | | | | B | | | |
C - series USB | | | | | | | | C | | | |
- none | | | | | | | | | | | |
|
---|
display | D - 4 digit display | | | | | | | | | D | | |
---|
|
---|
memory | M - FLASH memory | | | | | | | | | | M | |
---|
|
---|
switch | S - contact relay, 2x open collector + LED | | | | | | | | | | | S |
---|
|
---|